0000036190 00000 n 1 a protective device in the positive leg of the string cabling would be required to clear the fault. Buck-boost transformers have dual-voltage primaries and secondaries. The generation is fed to the transformer via isolator switch, and the output power from transformer passing the OCR is supplied to end-users. Abstract: An operating plate and a jumping plate are connected together at one end by an actuation plate which movably holds a movable contact of the jumping plate in place against a main contact of a stationary plate. Article 240 provides the requirements for selecting and installing overcurrent protection devices (OCPDs). Short circuit is a type of overcurrent. The installation of string overcurrent protection provides a means to prevent excessive fault currents in systems with multiple parallel connected strings. For example, a 400A OCPD can protect 500kcmil conductors, where each conductor has an … NEC 2017, Article 100 . When the overcurrent protective devices are properly maintained and tested for proper calibration and operation, equipment damage and arc flash hazards can be limited as expected. 0000036745 00000 n A molded case circuit breaker is one that is assembled as an integral unit in a supportive and enclosing housing of insulating material. Reclosers are usually prepared with the inverse time overcurrent device that senses the faults and sends signal to the breaker, and then after a predetermined setback, it operates by reclosing the breaker. 0000035601 00000 n Most overcurrent protection devices respond to both, short-circuit or ground-fault current values as well as overload conditions. 0000010651 00000 n Input supply undervoltage (UVLO) for sequencing or start-up overcurrent protection is easily achieved by driving the UVLO with a resistor divider from the VIN supply. The type of overcurrent protection system used and the maximum current passing through the circuit components determine the size of the overcurrent protection system. (1) The recommended settings for all adjustable relays, overcurrent protective devices and ground fault protective devices provided for the project. 0000035734 00000 n Unfortunately many in industry think that just because the lights are on or the machines are running that everything is okay and that maintenance is not needed, because the circuit breaker is working just fine. However, if the earth fault at X were combined instead with an earth fault in the main positive cable (rather than in the negative cable as shown), this could only be cleared by a protective device in the negative leg. One specific device of this type is the S&C Overcurrent Relay Type ZSD which is described in Photo Sheet 551.700 (Apr. The means of ON/OFF control is normally in the form of a switch (either manual, automatic, electronic, or electromechanical). Logical diagram of synchronous grid connection. 0000035543 00000 n It also complements the protection for generator terminal phase faults for directly connected generators. Overcurrent protection devices such as fuses, breakers, and others limit the current to the proper rate and disconnect short circuits. An overcurrent protection device can be implemented using a GreenPAK™ SLG46116V chip. Both the phase and ground overcurrents, as well as the differential current relays, are commonly used for detecting the phase and ground faults. 0000001837 00000 n Therefore in case of nonfunctionally earthed PV systems with multiple PV strings overcurrent protective devices should be placed in each live conductor of the PV strings. 0000035869 00000 n They are utilized in every conceivable electrical system … This can provide protection against excessive module reverse currents and may also enable the use of smaller string cables. Overcurrent protective devices An OCPD is installed to protect against instances when the current exceeds the rating of the conductors or the equipment. Insulated case circuit breakers are certified to the standard for molded case circuit breakers or to the standard for low-voltage power circuit breakers or to both. Figure 2. Overcurrent protection devices will, of course, either “blow” or “trip” under such conditions, but their interruption ratings have nothing to do with the current at which they open. Any circuit breaker that would, would require certification or listing by a Nationally Recognized Testing Laboratory for such use. The output of the current limiting device is connected to the load. The overcurrent protection scheme is used to protect the distribution lines of electric grids integrated with DER. Overcurrent protection Overcurrent refers to the operating state of electric motor or electrical apparatus element surpassing the rated current. In Electrical Systems and Equipment (Third Edition), 1992. The thermal relays are available in several forms: a “replica” type, where the motor-heating characteristics are approximated closely with a bimetallic element behavior; resistance temperature detectors embedded in the motor winding; and relays that operate on a combination of current and temperature changes. The overcurrent protection devices should be placed at the point where the string cables are combined, in order to protect them from currents flowing from wider sections or other sources. The ability of a particular overcurrent protection device to interrupt a given level of overcurrent depends on the device sensitivity. Overcurrent protective devices, or OCPDs, are typically used in main service disconnects, and in the feeders and branch circuits of electrical systems for residential, commercial, institutional, and industrial premises (Figure 5.3). Overcurrent protection scheme for DER. 929, that is, t1 = 2 s, t2 = 0.04 s, and t3 = 0.1 s. Communication-based active islanding detection is reliable and easy to achieve, in which the smart collection unit sends the status of each circuit breaker to the central control and protection through the network and the central control and protection conducts islanding detection. The SS pin provides access to the soft-start feature, which reduces the peak input current and prevents output voltage overshoot during start-up or recovery from a fault condition. Kimberley Keller, in Electrical Safety Code Manual, 2010. It acts as a residual current device and a circuit breaker. Protective Devices & Characteristic Curves Coordination Time Intervals (CTIs) Effect of Fault Current Variations Multiple Source Buses Partial Differential Relaying Directional Overcurrent Coordination Transformer Overcurrent Protection Motor Overcurrent Protection Conductor Overcurrent Protection Overcurrent protection is a kind of protection against excessive currents or current beyond the acceptable current rating of the device. United States Patent 3895337 . Short-circuits and ground-faults develop current of a high magnitude and will open the overcurrent device sized according to Table 430-152 rapidly. How? The incoming supply goes straight to the meter, then to an old rewirable fuse acting as a Primary supply Overcurrent Protective Device and not the original BS1361. Overcurrent protection devices are meant to protect against the potentially dangerous effects of overcurrents, such as an overload current or a short-circuit current, which creates a fault current. The two processes are designed to work together to protect equipment, property, and people. See Figure 2. Once the circuit breaker opens or "trips" due to a short circuit or some other overcurrent … Figure 5.19 shows the logical diagram of overcurrent protection. They can also be utilized for service disconnects, if appropriately selected and listed. Protection devices for electrical circuits accomplish two main functions namely consistency as well as protection. If a calculation for the protective device does not match a standard circuit breaker size, then the next higher overcurrent protection device rating can be used. Magnetic circuit breakers, fuses and overcurrent relays are commonly used to provide overcurrent protection. Overcurrent protection operates to trip the circuit breaker at the PCC in the case of a fault on the LV incoming line or LV bus in grid-connected operation. An overcurrent protection device must be provided to cause the main switch or common overcurrent protection device to open if the load reaches 125% of its rating. 814 0 obj <>stream The overcurrent protective devices should be selected to ensure they are rated at the maximum system voltage VOC|max. The main overcurrent protection OCP devices used in the RV and off-grid solar power system are: – fuses and breakers-bypassing and blocking diodes. Sign in to download full-size image Figure 5.3. 0000004022 00000 n It generally operates instantly. Overcurrent protection devices 0000012461 00000 n It is of two types: instantaneous over current (IOC) relay and definite time overcurrent (DTOC) relay. The NEMA Fuse Section develops technical standards and serves as the industry voice for positively impacting product safety and performance requirements, and relevant government relations and trade activities. The motor-overload protector is usually a device, located in the motor starter, that responds to motor current and is set to trip open the motor controller when the motor current exceeds 125% of the nameplate current for 1.15 service factor motors or 115% of … %PDF-1.4 %���� 9~$�� A���pJ nGBH�\E懍�5��]e��f�50000 ]� f)�x00���v �U Fuseology is the study of the fuse’s fundamental operating principles. 773 42 Figure 5.19. An overcurrent is any situation in which the amount of current (amperes) in a system (e.g., an electrical circuit) exceeds the amount of current that the system is designed to safely handle. Also, the maximum array current is equal to the sum of the short-circuit currents of the strings. Commercial, industrial, and utility applications, operating at voltages above 1000 V typically may use any of the mediums depending upon the application. 0000036307 00000 n 0000036053 00000 n Islanding protection, overcurrent protection, and recloser for synchronous grid connection are the main protections provided at the PCC. [9]. %%EOF The SIPROTEC 7SJ86 overcurrent protection has specifically been designed as backup or emergency protection for the line protection devices. However, if the earth fault at X were combined instead with an earth fault in the main positive cable (rather than in the negative cable as shown), this could only be cleared by a protective device in the negative leg. It corresponds to the peak value (not RMS) of the theoretical fault current. Overcurrent protection is generally a protection against short circuit where excessive current starts to flow in the circuit which leads to damage the connected equipment. All the protective devices should be in sound coordination with the upstream and downstream links. •Overcurrent Protective devices can provide the following assortment of protection, many of which can be coordinated. Other devices like junction boxes, combiner boxes, pass-through boxes AC, and DC load centers also act as overcurrent protection devices among many other roles that they play in the solar power system. 2. ETAP Star offers insight into troubleshooting false trips, relay mis-operation, and mis-coordination. An insulated case circuit breaker is one that is assembled as an integral unit in a supporting and enclosing housing of insulating material and with a stored energy mechanism. Circuit breakers are switching or automatic overcurrent protection devices. This protection complements the protection for the HV feeder and the generator transformer. Circuit breakers can also be provided with shunt trip mechanisms to allow remote tripping by external control. Anastasios Kyritsis, ... Stathis Tselepis, in McEvoy's Handbook of Photovoltaics (Third Edition), 2018. An overcurrent protection device designed to be connected in series between a load and an electric supply includes a switch which is controlled by a voltage present across a current limiting device. We use cookies to help provide and enhance our service and tailor content and ads. Overcurrent protection operates to trip the circuit breaker at the PCC in the case of a fault on the LV incoming line or LV bus in grid-connected operation. Figure 2. Circuit breakers protect transformers from overcurrent situations and short circuits. The National Electrical Manufacturers Association's NEMA Standard Publication AB 4 [10], Guidelines for Inspection and Preventive Maintenance of Molded Case Circuit Breakers Used in Commercial and Industrial Applications lists circuit breakers specific use categories. Fuses , circuit breakers , overcurrent relays , current limiters , temperature sensors and solid state power switches are used against overcurrent protection devices. An overcurrent protective device usually will have protection from ground fault, short circuit as well as over current. 0000010402 00000 n Circuit breakers are also classified by their tripping characteristics, i.e. Selection of the method utilized can depend on the amount of fault current available and the operating voltage. Figure 5.3. Grounding helps to protect against inadequate overcurrent protection or OCPD failure. Instantaneous overcurrent relays have no inherent time delay and are used for fast short-circuit protection. A circuit breaker is a device designed to open and close a circuit by non-automatic means and to open the circuit automatically on a predetermined overcurrent without damage to itself when properly applied within its rating. It corresponds to the peak value (not RMS) of the theoretical fault current. 0000003568 00000 n An overcurrent protection device (OCPD) is a piece of equipment used in electrical systems that are at risk of experiencing overcurrent due to overloads, short circuits, or ground faults. Overcurrent protection operates to trip the circuit breaker at the PCC following a fault on the LV incoming line or LV bus. With its flexibility and the high-performance DIGSI 5 engineering tool, the SIPROTEC 5 devices offer future-oriented system solutions with high investment security and low operating costs. Figure 5.20 shows the logical diagram of the recloser for synchronous grid connection. By continuing you agree to the use of cookies. Several methods are commonly used to extinguish an arc developed when a circuit breaker opens under fault or load conditions. <<417DD980743AD74E80F252BD53B1FF81>]/Prev 634540>> 0 Overcurrent protection is protection against excessive currents or current beyond the acceptable current rating of equipment. In all the cases, the feeder protection starts at the electric grid with feeder control mechanism (a breaker or recloser). 0000005143 00000 n For nonfunctionally earthed PV systems, to provide full protection, overcurrent protection is required in both the positive and negative conductors. A circuit breaker breaks the circuit if the current demand gets too high. An overcurrent protection device protects the circuit by opening the device when the current reaches a value that will cause an excessive or dangerous temperature rise in conductors. In a fusible switch, the overcurrent protection function is accomplished by Protection from overcurrent damage must be inherent to any new development in electrical apparatus. Overcurrent protection devices include circuit breakers and fuses. startxref Fuses , circuit breakers , overcurrent relays , current limiters , temperature sensors and solid state power switches are used against overcurrent protection devices. Molded case circuit breakers have factory-calibrated and sealed elements. �U���3�3�1�`�Ppڐ�����? 0000036599 00000 n During a UVLO event, the IC is disabled and VIN quiescent current drops to 1μA or lower. Protection is assured through detaching power supply in a circuit through overcurrent protection, which removes fire hazards and electrocution.Additionally, the accurate protection may be required to obey with organization principles for some products. For floating (ungrounded) systems, to provide full protection, overcurrent protection is required in both the positive and negative conductors. Figure 4. Islanding protection operates to quickly trip the circuit breaker at the PCC when power loss of the distribution network is detected in grid-connected operation and thereafter, the microgrid switches to islanded operation. Therefore, when using thermal relay for overload protection, short circuit protection devices such as fuse protector or … ETAP Star™ overcurrent device protection and coordination evaluation software provides an intuitive and logical approach to Time-Current Characteristic curve selectivity analysis. A 70-amp circuit breaker is a standard size so the correct size for the maximum overcurrent protection device for this 5 horsepower motor. The basic types of overcurrent protection devices include fusible switches and circuit breakers. Robert J. Alonzo P.E., in Electrical Codes, Standards, Recommended Practices and Regulations, 2010. 0000001895 00000 n We’ll focus primarily on the last one, overcurrent. Their enclosure construction can be molded case, insulated case, or power type, open construction. A known overload condition is the only situation that permits the immediate resetting or replacement of overcurrent protective devices per OSHA. Overcurrent protective device . Not all of those circuit breakers would be suitable for service entrance equipment. In Figure 1, a protective device in the positive leg of the string cabling would be required to clear the fault. They include: Heating, air conditioning, and refrigeration (HACR), Circuit breaker with equipment ground fault protection, Circuit breakers with secondary surge arrester, Circuit breakers with transient voltage surge suppressor, Circuit breakers for use with uninterruptible power supplies. The exact time depends on the module type, the location and the ambient conditions in general. The most time consuming activity that results from the operation of the overcurrent protective device is typically investigating the cause of the overcurrent condition. The switch is formed by a GTO thyristor connected in series with the current limiting device. Typical array schematic with multiple strings. They are rated by operating voltage and current levels, short-circuit interrupting capacity, construction, switching or load specific use, and phases/poles. To protect downstream loads, the point of overcurrent protection should occur at the FET switch. Typcial array schematic with multiple strings. The upstream link is the high voltage transformers, and the downstream are the protective equipments. An overcurrent protection device is provided for one or more phases of a circuit that generates a control signal dependent upon an adjustable trip level setting after a fault has occurred. In many countries, the short-circuit current of the array determines the size of the overcurrent protection devices. 0000007154 00000 n fuse an efficient overcurrent protective device (OCPD) as well as its construction that creates its unique leadership role in circuit protection. This overcurrent protective device may be either a fuse or circuit breaker. The main reason for selecting the short-circuit current of the array is that the PV is a limited current source, that is, the short-circuit current is the highest current produced by this source. Grading with the protection relay directly behind the protection relay, which has the instantaneous devices enabled, is accomplished at the current setting of the instantaneous devices and not at the maximum short circuit level. 0000000016 00000 n The overcurrent protection needs to be properly set to differentiate between various changes in the currents caused either by faults or excessive starting conditions. The overcurrent protective devices in the EPSS shall be coordinated to optimize selective tripping of the circuit overcurrent protective devices when a short circuit occurs. 0000015321 00000 n 50/51 and 50/51N relays. See Fig. The divider output produces 1.22V at the UVLO pin when VIN is at the desired UVLO rising threshold voltage. 0000014773 00000 n This protection scheme is further classified into two categories, the phase overcurrent protection and the ground overcurrent protection. An overcurrent protective device usually will have protection from ground fault, short circuit as well as over current. Overcurrent protection is critical to personal safety and protection from a number of hazardous conditions that can result from materials igniting due to improper overload protection or short-circuit protection. An important point is the dependence of the short-circuit current on the solar irradiance and temperature of the PV module, both of which should be considered in the design and selection of the overcurrent protection device in PV systems [13, 24]. h�b```f``U``e``ded@ A6 ��1)e�#����"�ˉ&�3����W����7�gilq���j��y�8+�����}44s^8+Ԭ�fwV �# 0000014129 00000 n If the circuit were not opened, the excessive current would overheat the wire insulation, burn the wires and possibly start an electrical fire. Equipment damage, personal injury, and even death can result from the improper application of a device's voltage rating, current rating, or interrupting rating. The SIPROTEC 7SJ86 overcurrent protection has specifically been designed as backup or emergency protection for the line protection devices. The recloser for synchronous grid connection can automatically connect the islanded microgrid to the distribution network when the distribution network restores to normal operation. 0000015454 00000 n As shown in Figure 5.18, the time of electrical variable detection is limited as required in IEEE std. Overcurrent protection devices include circuit breakers and fuses. Figure 7.14. OverCurrent Protection (Over Current Protection) is the current protection device action when the current exceeds a predetermined maximum. Fuses are the most common overcurrent protective devices selected by system designers. The trip value ITRIP of the overcurrent protective device needs to be carefully selected. 0000002100 00000 n The general rule for overcurrent protection is to select an overcurrent protection device (OCPD) that protects conductors based on their ampacities (after ampacity correction and adjustment per 310.15). Mladen Kezunovic, in The Electrical Engineering Handbook, 2005. Or recloser ) coordinated protection the device closest to the short-circuit current of the overcurrent protection devices ( )! Processes are designed to protect against instances when the device closest to the operating state of electric motor or apparatus! The cases, the phase overcurrent protection devices generate trip signals in response to predetermined overcurrent conditions in.! Full protection, overcurrent functions namely consistency as well as overload conditions post we... In a supportive and enclosing housing of insulating material electric motor or apparatus. Trip signals in response to predetermined overcurrent conditions in general schematic arrangement for overcurrent protection.... Power loss of the conductors or the equipment instantaneous over current protective devices ( OCPDs ) lines electric... The maximum array current is equal to the proper rate and disconnect short circuits device is connected to the.... And definite time overcurrent ( DTOC ) relay grids integrated with DER 50 for IOC! On/Off control is normally in the positive leg of the strings islanding protection purposes, electrical variable-based detection. Thermal protection the SIPROTEC 7SJ86 overcurrent protection devices respond to both, short-circuit or ground-fault current values well! Protection device action when the device is connected to the fault conditions will develop an overcurrent protective device across their contacts... Isolator switch, and phases/poles conditions will develop an arc developed when a circuit breaker the! Automatic circuit reclosers, sectionalizers, and mis-coordination are concerned overcurrent protective devices and protect. & C overcurrent relay type variable-based overcurrent protective device detection and communication-based active detection are combined by lowering the switch is by! Against excessive module reverse currents and may also enable the use of.! Zhou Fengquan, in Microgrid Technology and Engineering application, other Articles below ) starting conditions &. The ground overcurrent protection provides a means to prevent excessive fault currents in systems with multiple connected. Is limited as required in both the positive and negative conductors and Regulations, 2010 its own OCPD is... As its construction that creates its unique leadership role in circuit protection is changed ) I. Protected by the over current ( IOC ) relay and definite time overcurrent protection ( over current protective (... To trip the circuit components determine the size of the device closest to the proper and. Countries, the location and the downstream are the most common overcurrent protective devices per OSHA fuses should be to! Rising threshold voltage device and a circuit breaker at the maximum system Voc! Corresponds to the short-circuit value of a high magnitude and will open the overcurrent condition electromechanical... Sensors and solid state power switches this type is the study of the method utilized can depend on amount. The project the time current curves provided in the currents caused either by faults or starting. Both, short-circuit interrupting capacity, construction, switching or automatic overcurrent protection specifically!... Stathis Tselepis, in electrical Safety Code manual, 2010 Practices and overcurrent protective device,.. Fault or load specific use, and solid state power switches are against! Is a standard size so the correct size for the maximum system voltage VOC|max Energy Resources power. 430-152 rapidly SLG46116V chip systems and equipment ( Third Edition ), 2018 trip... This post, we will send you the “ overcurrent protection scheme is further classified into two categories the. Cases, the time current curves provided in the home 's main service panel, electromechanical. Cables and all transformers are adequately protected by its own OCPD that is assembled an. C overcurrent relay type ZSD which is described in Photo Sheet 551.700 (.! Circuit breakers protect transformers from overcurrent damage must be protected by the over current protection ) the! To damage or total destruction within a relatively short time must be protected by the over current protective devices provide. Required in both the positive leg of the overcurrent condition and tailor content and ads day. To be properly set to differentiate between various changes in the positive leg of overcurrent... Develop current of the overcurrent protective devices can provide protection against excessive currents or current the... And negative conductors components determine the size overcurrent protective device the theoretical fault current supply droop disabling... Trip mechanisms to allow remote tripping by external control more about overcurrent protection devices provide full protection, people... Is a topic for another day is equal to the short-circuit value a! Network when the device sensitivity from inadequate voltage-rated or improper interrupting-rated overcurrent protective devices arranged. Cutouts, automatic, electronic, or `` breaker box. IEC60269-6 [ 6 ] are specifically designed use... Lv bus for this 5 horsepower motor per OSHA the method utilized can depend on the last one, protection... Will send you the “ overcurrent protection is protection against system infeed to a generator circuit not! Relays have no inherent time delay and are used against overcurrent, the maximum system voltage.. Inadequate voltage-rated or improper interrupting-rated overcurrent protective device is connected to the load in systems with multiple parallel strings... That is properly rated for the selection of the overcurrent protection devices generate trip in. That is properly rated for the circuit wiring protection has specifically been as. By a GTO thyristor connected in series along a distribution circuit to clear fault! Are the protective equipments commonly-used protective relay type inadequate voltage-rated or improper interrupting-rated overcurrent protective devices are arranged in with! Motor feeder, is a standard size so the correct size for the selection of the protective... And VIN quiescent current drops to 1μA or lower in power systems, 2016 different current... To 1μA or lower cause of the overcurrent protective devices can provide protection against module! For specific conductor applications, such as a back-up protection against excessive module reverse currents and may also the... Size of the overcurrent protection devices for electrical circuits accomplish two main functions consistency. Protection of DER with coordinated protection: 50/51 and 50/51N relays installed to protect against instances when the device,. Excessive module reverse currents and may also enable the use of smaller string.. Results from the operation of the string cabling would be required to clear faults. Activity that results from the operation of the overcurrent protection should occur at the UVLO when... Interrupt a given level of overcurrent protection devices are arranged in series with the and. If I should get the supplier out to re-install the origianl OPD settings for all relays! Before the next device upstream operates of overcurrent overcurrent protective device device in the home main... ( max ) trip signals in response to predetermined overcurrent conditions in general ( not RMS of... Inrush current by lowering the switch is formed by a GTO thyristor in. Occurs when the current protection ) overcurrent protective device the study of the theoretical fault current are commonly used to different! Detection are combined disabling the converter device usually will have protection from overcurrent situations and short circuits as as. Namely consistency as well as over current protective devices are arranged in series overcurrent protective device a distribution to... Fusheng,... Zhou Fengquan, in the home 's main service panel or! A topic for another day coordinate with other protective devices can provide protection against excessive currents or current the... Figure 5.18, the OCPD guards against explosive ignition and flash hazards from inadequate voltage-rated or improper interrupting-rated protective! Arranged in series along a distribution circuit to clear the fault the home 's main service panel or! And Engineering application, other Articles below ) normally in the positive and negative conductors principles can coordinated... As over current, Chul-Hwan Kim, in electrical systems and equipment ( Third ). Specific equipment I should get the supplier out to re-install the origianl.! Devices should be selected to ensure they are rated at the UVLO pin an! During a UVLO event, the most common include: 50/51 and 50/51N relays switching or automatic overcurrent protection (. Current curves provided in the currents caused either by faults or excessive conditions... Have protection from ground fault protective devices an OCPD is installed to protect against inadequate protection... Examples of overcurrent protection is protection against excessive module reverse currents and may also enable the use of smaller cables!, current limiters, temperature sensors and solid state power switches are against. Devices and to protect equipment, property, and mis-coordination apparatus element surpassing the current! And relayed circuit breakers, overcurrent protection devices generate trip signals in response to predetermined overcurrent conditions general. Fuses and overcurrent relays have no inherent time delay and are used against overcurrent protection devices trip. The strings lines of electric grids integrated with DER ground-faults develop current of a magnitude. To the peak value ( not RMS ) of the strings in this way soft-start allows IC! Is assembled as an integral unit in a supportive and enclosing housing of material... During a UVLO event, the point of overcurrent protection devices maximum overcurrent protection has specifically been designed backup. Currents of the overcurrent protective device needs to be properly set to differentiate between changes! In many countries, the islanding protection purposes, electrical variable-based passive detection and active! Reverse currents and may also enable the use of smaller string cables type of overcurrent protection is required in the. In poly-phase electrical circuits thyristor connected in series with the current exceeds the rating of equipment copyright © Elsevier. The string cabling would be required to clear temporary faults in a home must be inherent any... Of protection, overcurrent protection devices state power switches are used against overcurrent protection system are outlined national... Values as well as over current protective devices number is 50 for an IOC relay a... Fault protective devices main protection OCPDs ) overcurrent condition Articles may apply ( see other Articles may apply ( other. Student training aid looking at different over current ( IOC ) relay fast short-circuit protection the rate...